PHYSICAL DESCRIPTION
- Products: multi mode Fiber optic cable
- Tube Filling Compound: Thixotropic jelly /N
- Fiber Type: 50/125 OM4
- Tube material: PBT ( Polybutylene Terephthalate)
- Armored: N
- Packing Detail
- Fiber Count: 6,8,12,24,
- Tube Outer/Inner Diameter(mm): 3.0/2.0 ±
- Cable Diameter(mm): 4.2*-12
- Cable Weight(kg/km): 45±
- Length/ Drum: 2000 m Drum ±5%
- Ripcord: Polyester cord
- Outer Jacket: PE,MDPE, LSZH
Mechanical and Environmental PropertiesÂ
Physical tests                                Value                          Standard
Tensile Strength                                 2700 N (During Installation)       IEC 60794-1-E1
                                                1700 N (During Operation)
Impact Resistance                               10J, 3 impacts                    IEC 60794-1-E4
Crush Resistance                                220 N/cm                        IEC 60794-1-E3
Temperature Cycling                             -40 to +70 °C                     IEC 60794-1-F1
Flame Retardancy                               According to IEC 60332-3          IEC 60332-3
Cable Bending Radius
Bend Radius (during installation)                 20x Cable Diameter                IEC 60794-1-2-E11A
Bend Radius (during Service) 1                    0x Cable Diameter                 IEC 60794-1-E11
Repeating Bending                               20x Cable Diameter                IEC 60794-1-E6
Temperature Range)
Operation Temperature                          -40 to +70 C                       IEC 60794-1-2-F1
Storage and Transportation Temperature          -40 to +70 C
Installation Temperature                         -30 to +60 C
Optical Characteristics
Attenuation (max): 3.5 dB/km (850 nm) 1.5 dB/km (1300 nm)
Bandwidth (Laser EMB): 2000 MHz.km(850) 500 MHz.km (1300nm)
Bandwidth (Overfilled): 3500 MHz.km (850 nm) 500 MHz.km (1300 nm)
Numerical Aperture:0.2±0.015
Core Diameter: 50 ± 2 μm
Cladding Diameter: 125 ± 1μm
Core/Clad Concentricity error: ≤ 1 μm
Cladding non-circularity:≤ 0.7 %
Coating Diameter:242 ± 5 μm
Proof Test: ≥ 100kpsi or 0.7GPa
Bandwidth (Laser EMB): 2000 MHz.km(850) 500 MHz.km (1300nm)
Bandwidth (Overfilled): 3500 MHz.km (850 nm) 500 MHz.km (1300 nm)
Numerical Aperture:0.2±0.015
Core Diameter: 50 ± 2 μm
Cladding Diameter: 125 ± 1μm
Core/Clad Concentricity error: ≤ 1 μm
Cladding non-circularity:≤ 0.7 %
Coating Diameter:242 ± 5 μm
Proof Test: ≥ 100kpsi or 0.7GPa