1 Pair (2 Core) Foil + Braid Shielded RS-485 / BACnet MS/TP / Modbus RTU Bus Cable

KEY FEATURES

  • 1 Pair (2 Core) controlled twisted-pair construction
  • Overall foil + tinned-copper braid + drain wire
  • 120 Ω nominal protocol-design target
  • 18, 20, 22, 24 AWG Series options
  • PVC, LSZH and outdoor PE jacket choices
  • Exact searchable ordering code for every standard combination

Supplied in the UAE by TMT Global UAE from our Sharjah warehouse (Industrial Area 18) and Dubai office (Naif), for projects in Dubai, Sharjah, Abu Dhabi and across the Emirates. Request a quote

0 People watching this product now!
chat with sales
Description

Choosing the 1 Pair (2 Core) Foil + Braid Shielded RS-485 / BACnet MS/TP / Modbus RTU Bus Cable

Choose bus cable by protocol family first, because characteristic impedance and pair construction must match the bus. Then pick the screening and jacket for the route. Jacket options: PVC for general indoor routes, LSZH where low smoke and zero halogen are specified for occupied buildings, PE for outdoor routes.

  • Protocol: RS-485 / BACnet MS/TP / Modbus RTU
  • Impedance: 120 Ω nominal
  • Cores / pairs: 1 Pair
  • Conductor size: 18 AWG / 20 AWG / 22 AWG / 24 AWG
  • Conductor: Solid or stranded bare-copper conductor
  • Screen: Overall foil + tinned-copper braid + drain wire
  • Package: 305 m standard package

Related options in this range: 2 Pairs (4 Core) Foil Shielded RS-485 / BACnet MS/TP / Modbus RTU Bus Cable · 1 Pair (2 Core) Foil Shielded RS-485 / BACnet MS/TP / Modbus RTU Bus Cable · 2 Pairs (4 Core) Foil + Braid Shielded RS-485 / BACnet MS/TP / Modbus RTU Bus Cable · 1 Pair (2 Core) Foil Shielded CAN Bus / CANopen Bus Cable

Order code: 02B-RS. Send us the length, jacket and quantity for a project quotation and datasheet.

TMT 1 Pair (2 Core) Foil + Braid Shielded RS-485 / BACnet MS/TP / Modbus RTU Bus Cable Series

TMT Global 1 Pair (2 Core) Foil + Braid Shielded RS-485 / BACnet MS/TP / Modbus RTU Bus Cable is a controlled protocol-bus cable family for bacnet ms/tp building-management trunks and related industrial or building-automation networks. This page covers the 1 pair (2 core), foil + braid shielded and 120 Ω nominal electrical family; the ordering table lists the exact jacket and conductor-size order codes.

KEY FEATURES

  • 1 Pair (2 Core) controlled twisted-pair construction
  • Overall foil + tinned-copper braid + drain wire
  • 120 Ω nominal protocol-design target
  • 18, 20, 22, 24 AWG Series options
  • PVC, LSZH and outdoor PE jacket choices
  • Exact searchable ordering code for every standard combination

TYPICAL APPLICATIONS

  • BACnet MS/TP building-management trunks
  • Modbus RTU and generic EIA/RS-485 serial links
  • PLCs, VFDs, HMIs, RTUs and SCADA equipment
  • Long-distance balanced data transmission in industrial and building systems
  • Shielded construction is the commercial norm; foil + braid is preferred for higher-EMI routes.

Technical Specification

AWG / NOMINAL AREA / SERIES AVAILABILITY

Additional information
AWG18 awg, 20 awg, 22 awg, 24 awg
ColourBlack, Blue
BrandTMT Global
Jacket TypePVC, LSZH, PE Outdoor
Length305 m